Industrial-grade network environmental monitoring instruments utilizing high-accuracy sensing elements from Switzerland & Germany.
Interface: RJ45 Ethernet
Parameters: TVOC, Ozone, Temp, Humidity
Protocols: TCP/IP, Modbus TCP
Target Gases: TVOC, HCHO, T/H
Compliance: CE, FCC, RoHS
Parameters: TVOC, Ozone, T/H, Dew Point
Telemetry: Ethernet PoE
Aerosols: Carbon Monoxide, IAQ index
Architecture: Integrated Embedded Gateway
Sensors: Electrochemical + CMOSens®
Storage: Local non-volatile memory buffer
Target: VOC emissions & Formaldehyde
Application: Industrial emission & battery storage
Sensors: Dual electrochemical elements
Interfaces: Ethernet RJ45 + RS485
Compliance: IEC 61000 EMC criteria
An in-depth analysis of high-precision humidity and temperature sensing technologies in mission-critical deployments.
The global demand for high-precision environmental instrumentation is undergoing a rapid evolution, driven by the emergence of high-density AI computing centers, advanced biopharmaceutical cleanrooms, and automated semiconductor fabrication plants. Modern infrastructure demands environmental telemetry that goes beyond traditional thermostats. The integration of high-sensitivity relative humidity (RH) transducers and platinum resistance temperature detectors (RTDs) is critical to maintaining physical state controls and structural stability.
In data center thermal management, for example, the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) specifies stringent dry-bulb temperature and dew point ranges to prevent electrostatic discharge (ESD) on the lower end and condensation corrosion on the upper end. Achieving these limits requires sensors with a measurement accuracy of ±0.2°C for temperature and ±1.5% RH for humidity, combined with low drift over long operational life cycles.
Yingchuanglihe partners with leading Swiss and German semiconductor foundries to integrate advanced CMOSens® and MEMS micro-sensor chips. The core relative humidity measurement is based on a capacitive polymer sensing element. The dielectric structure of the polymer shifts proportionally with the ambient water vapor concentration, producing changes in capacitance that are converted into high-resolution digital signals via on-chip 14-bit analog-to-digital converters (ADCs).
For temperature sensing, integrated bandgap silicon sensors or PT100/PT1000 platinum RTDs are used. These sensors are calibrated against standard reference systems to minimize self-heating effects and heat transfer from the processor board. By separating the sensing elements from the main network interface unit, we reduce the thermal load from Ethernet physical layers (PHY) and wireless microcontrollers, ensuring high accuracy.
Choosing the right telemetry protocol is critical for industrial setups. Yingchuanglihe offers three main connectivity solutions:
Beijing Yingchuanglihe Electronic Technology Co., Ltd. (established in 2007) is a specialized developer and manufacturer of environmental telemetry equipment. Over our 18-year history, we have evolved from a specialized local enterprise into an ISO9001-certified high-tech manufacturer with a modern 1,500 square meter production facility.
Engineered hardware categories designed for easy integration with modern supervisory control and data acquisition systems.
Designed for data centers and smart offices, these sensors support PoE (IEEE 802.3af) alongside standard DC 12-48V power inputs, providing a stable wired environmental monitoring connection.
These units integrate relative humidity and temperature monitoring with additional parameters, including barometric atmospheric pressure, carbon monoxide, TVOCs, ozone, and formaldehyde.
Battery-powered sensors for long-range, low-power telemetry. Optimized for agricultural fields, cold chain storage, and urban smart grids.
Our sensor systems are integrated into various demanding industrial environments worldwide.
Over a decade and a half of engineering development in specialized environmental instrumentation.
Our products undergo systematic compliance and calibration protocols to meet international regulatory frameworks.











Detailed performance parameters for key network sensor units.
Power: PoE (IEEE 802.3af) / DC 12-48V
Calculations: Temp, Humidity, Dew Point
Sensor: Precision Piezo-resistive cell
Parameters: Pressure + T/H + Dew Point
Probe Cable: 1-3 Meters PTFE Shielded
Target: Remote spaces, duct installation
Monitoring: CO (0-1000ppm), IAQ Index
Interface: Modbus TCP/IP Protocol
Operational details, validation processes, and interface specifications for engineers and system integrators.
Select from our production inventory. Click details for complete protocol maps and registers.
Probe: Extendable external probe options
Output: Modbus TCP/IP, RJ45 Interface
Gases: CO + general Indoor Air Quality
Power: PoE support (IEEE 802.3af)
Gases: Ozone, general VOC levels
Certification: CE LVD & EMC Compliance
Application: Industrial emission monitoring
Interface: RJ45 Ethernet, Modbus TCP
Type: High-performance multi-gas sensor
Integration: Building Management Systems
Wireless: Sub-GHz LoRaWAN network protocols
Battery: Up to 5-year operational life
Power: PoE / IEEE 802.3af standard
Parameters: T/H and real-time Dew Point
Frequency: Multiple band support (EU868/US915)
Application: Industrial agriculture, large storage