Custom APEM-5930G Ethernet IAQ & Carbon Monoxide with Temperature &Humidity Data Logger Manufacturer, Manufacturers

Model:APEM-5930G-IAQ-CO

This product is a high-performance industrial-grade sensor that integrates temperature, humidity, carbon monoxide (CO), and Indoor Air Quality (IAQ) monitoring functions into a single device. Utilizing a standard Ethernet interface, it provides users with stable, reliable, and real-time environmental data, serving as a key component for intelligent environmental monitoring and safety management systems.

Product Description

Applicable Scenarios

Underground parking garages and semi-enclosed corridors: to monitor CO buildup and general air pollution.
Schools, gyms, shopping malls, and other high-occupancy areas: for combined air quality and safety monitoring.
Hotel and restaurant kitchens: to detect gas leaks and pollutants from cooking.
Assisted living facilities and retirement communities: to protect the health and safety of vulnerable residents.

Product Features

1. Core Environmental Monitoring Functions
Temperature & Humidity: Utilizes high-precision digital sensors to monitor ambient temperature and humidity in real-time, providing data for comfort, energy savings, and equipment safety.
Carbon Monoxide (CO): Equipped with a highly sensitive solid-state electrochemical sensor to accurately detect carbon monoxide concentration levels. It provides effective early warning of potential safety hazards, serving as a critical safeguard for indoor safety and protection.
Indoor Air Quality (IAQ): Comprehensively monitors various Volatile Organic Compounds (TVOC) to fully assess indoor air pollution levels, safeguarding occupant health and productivity.
2. Powerful Input/Output & Control Interfaces
2-Channel Digital Input (DI): Accepts dry contact signals for monitoring the status of devices like door magnets, water leak sensors, and differential pressure switches, expanding security and equipment monitoring capabilities.
1-Channel RS485 to Ethernet: Acts as a protocol conversion gateway, easily integrating third-party devices using protocols like Modbus RTU (e.g., electricity meters, water meters, legacy sensors) into the Ethernet network for system integration.
1-Channel Relay Output (DO): Features Normally Open (NO) / Normally Closed (NC) contacts for programmable control of external devices. Enables automatic smart activation/deactivation of equipment like fans, alarms, or lights based on threshold violations.
3. Stable Networking & Power Supply
Ethernet Communication: 10/100M auto-adaptive Ethernet interface supporting multiple network protocols including MQTT, SNMP, Modbus TCP, and UDP for easy integration into existing LANs.
PoE Power Supply (802.3af): Supports power delivery over the Ethernet cable, eliminating the need for separate power wiring. This greatly simplifies installation, especially in challenging locations like ceilings or tight spaces. A standard DC power interface is retained as a backup.
4. Data Logging & Alarm Functions
Local Data Logging: The device features built-in memory capable of storing 100,000 data records, enabling cyclic logging of historical data for easy traceability and analysis.
Multiple Alarm Mechanisms: Allows users to independently set high/low alarm thresholds for each monitored parameter. Supports various alarm methods including local sound/light indicators, email notifications, or SNMP Traps.
5. Industrial-Grade Quality
Wide Temperature & Voltage Range Design: Operates reliably across a broad temperature range of -20°C to 65°C and in complex industrial electromagnetic environments.
Rugged Enclosure: Constructed with metal or high-strength flame-retardant plastic housing, offering excellent shielding and durability.

Parameter IAQ-CO-10-1000-01

Measurement Content Range Resolution Response Time
IAQ 0-10ppm 0.01ppm <3S(T90<15S)
CO 0-1000ppm 0.1ppm <3S(T90<30S)
Temperature -25~80℃ ±0.2℃(at 25℃); Real-time
Humidity 0~99.9%RH ±2%RH(at 25℃) Real-time
Table 2
Measurement Content IAQ, CO, Temperature, Humidity, Dew Point
Power Supply DC12~48V, POE power supply
Communication Protocol Modbus TCP, UDP, SNMP(V1.V2), MQTT
Communication Interface RJ45
Interface 2 channels DI input, 1 channel DO output, 1 channel RS485, 1 channel DC12V output
Alarm Light, sound, email alarm, protocol alerts
Screen Display 3.5 inch TFT color screen
Data Storage 100,000 records
Installation Screw fixation, Magnetic
Dimensions 100*135*35mm

Product Video

Product Dimensions

5930G Dimensions

Product Display

Ethernet-All-in-one-Sensor-1
Ethernet-All-in-one-Sensor-2
Ethernet-All-in-one-Sensor-3
Ethernet-All-in-one-Sensor-4
Ethernet-All-in-one-Sensor-7
Ethernet-All-in-one-Sensor-8
Ethernet-All-in-one-Sensor-9
Ethernet-All-in-one-Sensor-6
Power-over-Ethernet-Temperarue-and-Humidity-Web-Sensor-7
Power-over-Ethernet-Temperarue-and-Humidity-Web-Sensor-8

Selection Table

Gas Module Channel Gas Types Formula Range Resolution Response Time
SMELL-TVOC-200-01 S0 Odorous Gases SMELL 0-200ppm 0.1ppm < 3s (T90 < 15s)
S1 Volatile Organic Compounds TVOC 0-200ppm 0.1ppm < 3s (T90 < 15s)
NH₃-H₂S-100-10-01 S0 Ammonia NH₃ 0-100ppm 0.1ppm < 3s
S1 Hydrogen Sulfide H₂S 0-10ppm 0.01ppm < 3s (T90 < 30s)
SMELL-H₂S-200-100-01 S0 Odorous Gases SMELL 0-200ppm 0.1ppm < 3s (T90 < 30s)
S1 Hydrogen Sulfide H₂S 0-100ppm 0.1ppm < 3s (T90 < 30s)
NH₃-H₂S-100-01 S0 Ammonia NH₃ 0-100ppm 0.1ppm < 3s
S1 Hydrogen Sulfide H₂S 0-100ppm 0.1ppm < 3s (T90 < 30s)
ETO-O₂-100-25%-01 S0 Ethylene Oxide C₂H₄O 0-100ppm 0.1ppm < 3s (T90 < 30s)
S1 Oxygen O₂ 0-25%vol 0.01%vol < 3s (T90 < 30s)
ETO-O₂-10-25%-01 S0 Ethylene Oxide C₂H₄O 0-10ppm 0.01ppm < 3s (T90 < 80s)
S1 Oxygen O₂ 0-25%vol 0.01%vol < 3s (T90 < 30s)
PH₃-20-2000-01 S0 Phosphine PH₃ 0-20ppm 0.1ppm < 3s (T90 < 30s)
S1 Phosphine PH₃ 0-2000ppm 1ppm < 3s (T90 < 30s)
H₂-CO-4%-1000-01 S0 Hydrogen H₂ 0-4%vol 0.01%vol < 3s (T90 < 30s)
S1 Carbon Monoxide CO 0-1000ppm 0.1ppm < 3s (T90 < 30s)
H₂-CO-1000-01 S0 Hydrogen H₂ 0-1000ppm 1ppm < 3s (T90 < 30s)
S1 Carbon Monoxide CO 0-1000ppm 0.1ppm < 3s (T90 < 30s)
O₂-CO-25%-1000-01 S0 Oxygen O₂ 0-25%vol 0.01%vol < 3s (T90 < 30s)
S1 Carbon Monoxide CO 0-1000ppm 0.1ppm < 3s (T90 < 30s)
O₂-H₂S-25%-100-01 S0 Oxygen O₂ 0-25%vol 0.01%vol < 3s (T90 < 30s)
S1 Hydrogen Sulfide H₂S 0-100ppm 0.1ppm < 3s (T90 < 30s)
O₂-CO-25%-10000-01 S0 Oxygen O₂ 0-25%vol 0.01%vol < 3s (T90 < 30s)
S1 Carbon Monoxide CO 0-10000ppm 1ppm < 3s (T90 < 30s)
H₂S-CO-100-1000-01 S0 Hydrogen Sulfide H₂S 0-100ppm 0.1ppm < 3s (T90 < 30s)
S1 Carbon Monoxide CO 0-1000ppm 0.1ppm < 3s (T90 < 30s)
TVOC-CO-200-1000-01 S0 Volatile Organic Compounds TVOC 0-200ppm 0.1ppm < 3s (T90 < 15s)
S1 Carbon Monoxide CO 0-1000ppm 0.1ppm < 3s (T90 < 30s)
O₃-CO-5-10-01 S0 Ozone O₃ 0-5ppm 0.01ppm < 3s (T90 < 80s)
S1 Carbon Monoxide CO 0-10ppm 0.01ppm < 3s (T90 < 80s)
NO₂-CO-100-1000-01 S0 Nitrogen Dioxide NO₂ 0-100ppm 0.1ppm < 3s (T90 < 30s)
S1 Carbon Monoxide CO 0-1000ppm 0.1ppm < 3s (T90 < 30s)
SMELL-NH₃-5-10-01 S0 Odorous Gases SMELL 0-5ppm 0.01ppm < 3s (T90 < 30s)
S1 Ammonia NH₃ 0-10ppm 0.01ppm < 3s
TVOC-HCHO-10-5-01 S0 Volatile Organic Compounds TVOC 0-10ppm 0.01ppm <3s(T90<15s)
S1 Formaldehyde HCHO 0-5ppm 0.01ppm <3s(T90<80s)
TVOC-CO-10-1000-01 S0 Volatile Organic Compounds TVOC 0-10ppm 0.01ppm <3s(T90<15s)
S1 Carbon Monoxide CO 0-1000ppm 0.1ppm <3s(T90<30s)
TVOC-O₃-10-5-01 S0 Volatile Organic Compounds TVOC 0-10ppm 0.01ppm <3s(T90<15s)
S1 Ozone O₃ 0-5ppm 0.01ppm <3s(T90<80s)
TVOC-CO-10-01 S0 Volatile Organic Compounds TVOC 0-10ppm 0.01ppm <3s(T90<15s)
S1 Carbon Monoxide CO 0-10ppm 0.01ppm <3s(T90<30s)
TVOC-H₂S-10-100-01 S0 Volatile Organic Compounds TVOC 0-10ppm 0.01ppm <3s(T90<15s)
S1 Hydrogen Sulfide H₂S 0-100ppm 0.1ppm <3s(T90<30s)
SO₂-NO₂-5-01 S0 Sulfur Dioxide SO₂ 0-5ppm 0.01ppm <3s(T90<80s)
S1 Nitrogen Dioxide NO₂ 0-5ppm 0.01ppm <3s(T90<80s)
O₃-HCHO-5-01 S0 Ozone O₃ 0-5ppm 0.01ppm <3s(T90<80s)
S1 Formaldehyde HCHO 0-5ppm 0.01ppm <3s(T90<80s)
TVOC-CO-100-01 S0 Volatile Organic Compounds TVOC 0-100ppm 0.1ppm <3s(T90<15s)
S1 Carbon Monoxide CO 0-100ppm 0.1ppm <3s(T90<30s)
O₃-HCHO-100-50-01 S0 Ozone O₃ 0-100ppm 0.1ppm <3s(T90<80s)
S1 Formaldehyde HCHO 0-50ppm 0.1ppm <3s(T90<80s)
SO₂-NO₂-50-01 S0 Sulfur Dioxide SO₂ 0-50ppm 0.1ppm <3s(T90<15s)
S1 Nitrogen Dioxide NO₂ 0-50ppm 0.1ppm <3s(T90<30s)
SMELL-NH₃-5-100-01 S0 Odorous Gases SMELL 0-5ppm 0.01ppm <3s(T90<30s)
S1 Ammonia NH₃ 0-100ppm 0.1ppm <3s
SMELL-TVOC-5-10-01 S0 Odorous Gases SMELL 0-5ppm 0.01ppm <3s(T90<30s)
S1 Volatile Organic Compounds TVOC 0-10ppm 0.01ppm <3s(T90<15s)
NH₃-H₂S-10-5-01 S0 Ammonia NH₃ 0-10ppm 0.01ppm <3s
S1 Hydrogen Sulfide H₂S 0-5ppm 0.01ppm <3s(T90<30s)
PH₃-O₂-20-25%-01 S0 Phosphine PH₃ 0-20ppm 0.1ppm <3s(T90<30s)
S1 Oxygen O₂ 0-25%vol 0.01%vol <3s(T90<30s)
IAQ-CO-10-1000-01 S0 Air Quality IAQ 0-10ppm 0.01ppm <3s(T90<15s)
S1 Carbon Monoxide CO 0-1000ppm 0.1ppm <3s(T90<30s)
IAQ-HCHO-10-5-01 S0 Air Quality IAQ 0-10ppm 0.01ppm <3s(T90<15s)
S1 Formaldehyde HCHO 0-5ppm 0.01ppm <3s(T90<80s)
IAQ-O₃-10-5-01 S0 Air Quality IAQ 0-10ppm 0.01ppm <3s(T90<15s)
S1 Ozone O₃ 0-5ppm 0.01ppm <3s(T90<80s)

Document Download

PDF Icon
5930G Ethernet IAQ & Carbon Monoxide with Temperature & Humidity Data Logger Datasheet
Download Action 1 Download Action 2

Frequently Asked Questions

What parameters does the 5930G sensor monitor?
The device comprehensively monitors temperature, humidity, carbon monoxide (CO) concentration levels, and Indoor Air Quality (IAQ) / Volatile Organic Compounds (TVOC) in real-time.
Does the device support Power over Ethernet (PoE)?
Yes, it supports standard PoE power supply (802.3af), allowing both power and network connection via a single Ethernet cable for simplified installation. It also retains a standard DC power interface as backup.
What communication protocols are available for integration?
The sensor supports widely used communication protocols including Modbus TCP, UDP, SNMP (V1/V2), and MQTT, making it highly compatible with modern networking infrastructures.
How much history data can be saved locally?
The device features built-in memory capable of storing up to 100,000 data records locally, enabling cyclic data logging for ease of tracking and compliance analysis.
Can the 5930G trigger external hardware based on alarms?
Yes, it features a 1-channel relay output (DO) with Normally Open (NO) and Normally Closed (NC) contacts, which can be programmed to automatically trigger external ventilation, fans, alarms, or lights.
What mounting options are supported?
It supports two easy mounting configurations: standard screw fixation or a magnetic attachment system for flexible industrial deployment.